Effective use of the international building code.
2015 ibc roofing code.
Proper ventilation is also important for performance in cold climates and the ability to shed or retain snow must also be considered.
Fasteners for asphalt shingles shall be galvanized steel stainless steel aluminum or copper roofing nails minimum 12 gage 0 105 inch 3 mm shank with a minimum 3 8 inch diameter 10 mm head astm f 1667 of a length to penetrate through the roofing materials and a minimum of 3 4 inch 19 mm into.
Shingles must be tested in accordance with astm d 3161 class f 120 mph vasd to 150 mph vasd or astm d 7158 class g up to 120 mph or class h up to 150 mph.
Roof covering replacement building code requirements ibc 2015 page 1 of 1 roof covering replacement building code requirements asphalt shingles irc 905 2 ibc 1507 2 1.
Recovering and replacement which includes full removal of the existing roof.
The 2015 international building code section 1511 reroofing provides the building code requirements when reroofing.
International building code 2015 ibc 2015 most popular sections section 1011 stairways section 1006 number of exits and exit access doorways section 1004 occupant load section 508 mixed use and occupancy section 1005 means of egress sizing section 1017 exit access travel distance section 705 exterior walls section 706 fire walls section 1010 doors gates and turnstiles section 304 business group b.
For the first time the international existing building code 2015 edition iebc 2015 includes specific code requirements applicable to reroofing.
In areas where there has been a history of ice forming along the eaves causing a backup of water an ice barrier must be installed in accordance with chapter 15 of the 2015 ibc or chapter 9 of the 2015 irc.
2015 ibc residential roofing codes.
Iebc 2015 only is applicable where it is specifical ly adopted and in many cases iebc 2015 may not be adopted concurrently with ibc 2015 and irc 2015.
Fasteners for asphalt shingles shall be galvanized stainless steel aluminum or copper roofing nails minimum 12 gage 0 105 inch 2 67 mm shank with a minimum 3 8 inch diameter 9 5 mm head of a length to penetrate through the roofing materials and a minimum of 3 4 inch 19 1 mm into the roof sheathing.
Cold climates create unique conditions for roof design and prevention of ice and snow related damages.
The ibc applies to all occupancies including one and two family dwellings and townhouses that are not within the scope of the irc.
Ibc 2015 international building code.
Arrangement and format of the.
Partial shown the ibc applies to all types of buildings and structures unless exempted.
Reroofing projects are divided into two types.
Where the roof sheathing is less than 3 4 inch 19 1 mm thick the nails.
Roofs shall be covered with materials as set forth in sections r904 and r905.